Direct connection between the LME - LDE and a PC
is possible using the CPI adaptor. The CPI allows easy connection
between the instrument configuration port and the PC RS-232 port
(COM1/COM2).
PC-based EROConfig software speeds and simplifies
configuration by providing guided menus for complete instrument
set-up. EROConfig software also allows you to save and copy complete
instrument configurations.
New Timer Functions
Four timer functions are provided in the new version
of the LME- LDE. The timer provides control over the selection of
the working and standby (SP1/SP2) setpoints.
Timer - Mode 1
"Energy saving" mode.
Functional overview:
When the machine is not used for a predefined time, the instrument
switches to a standby temperature setting.
Typical applications:
Glue and laminating machines.
Variants:
"Guaranteed soak" timer operates when process is within defined
temperature limits.
"Output power off" function instead of maintenance temperature.
NOTE: With the timer running, the lower display
indicates time remaining
Timer - Mode 3
Same as "Cooking" mode but with "End of cycle" indication.
Typical applications:
Laboratory apparatus:
- Stirrer with hot plate
- Thermostatic baths
- Ultrasonic cleaning baths
- Incubators
Variants:
"Guaranteed soak" timer operates when process is within defined
temperature limits.
Maintenance temperature instead of "output power off" function.
NOTE: a special with internal audible
alarm is also available.
Timer - Mode 4
"Paint" mode.
Typical applications:
- Paint drying ovens
Functional overview:
The timer starts when SP2 is selected. If guaranteed soak is selected,
the timer starts when SP2 is reached. OP2 may be used to control
air recirculation during the drying period as well as indicating
the dryer is operating.
Variants:
"Guaranteed soak" timer operates when process is within defined
temperature limits.
"Output power off" function instead of "painting" temperature.
NOTE: During the dry phase the lower display shows
the remaining time.