32h8i 1/8 DIN Indicating Alarm Unit
with Scrolling Text Messaging

详细资料

Process Measurement
Temperature Measurement
Differential Measurement
Pressure Flow Monitoring
Level Monitoring
Furnace Over-Temperature
Process Protection
Strain Gauge Input
Extrusion Melt Pressure

 
EUROTHERM QUALITY & PERFORMANCE FOR THE BUDGET CONSCIENCE
Eurotherm's range of 3200i indicators offer accurate indication of temperature and process measurements. Process interlocks, including over temperature furnace limits, are implemented using relay output channels.

The emphasis is on ease of use. A simple Quick Start code is used to configure all the functions essential for indication and protecting your process. This includes input sensor type, measurement range and alarms making Out the Box operation truly achievable. In operation every parameter has a scrolling text message describing its function and is available in English, German, French, Spanish or Italian. More advanced features, including scrolling text messages, are configured using a PC based  configuration wizard which is an easy to use and instructive guide to all the functions available.

Universal Input
A wide range of temperature and process inputs can be selected using the front panel push buttons without the need for any hardware change. This provides easy on-site set up.

Process Alarms
Four internal alarm setpoints are provided. They can be used to energize up to three relay outputs, which can be latched if required. A special mode known, as ‘Alarm Blocking’ is available which ensures that when the unit is powered up an alarm must first enter a good state before the alarm becomes active. This is particularly useful for low alarms which can be blocked while the process is warming up.

Custom Text Messaging
Custom messages can be created with a PC tool and downloaded to the 3200i to display when an event, alarm or process condition occurs. This provides the operator with good visibility of what is happening in the process and provides messages that they can understand and act upon.

Recipes
Using a PC tool recipes can be created that can be used to change the operating parameters of the 3200i simply by selecting a recipe using the 3200i push buttons. This is very useful where multiple products are processed but require different parameters to be set. It can also be used to change the set-up of a indicator therefore allowing one unit to be used as a spare for multiple applications.

Analogue Retransmission
The measured process value can be retransmitted as either a mA or voltage signal with a selection of outputs including 4-20mA and 0-10Vdc. In the 32h8i this signal is isolated from all other electronics within the unit.

Digital Communication
All units support both EIA232 and EIA485 communication using the Modbus protocol as a slave device. It is also possible to digitally retransmit one parameter using a Modbus broadcast to all other Modbus devices on the network.

Configuration Adaptor
PC configuration to all 3200i indicators can be achieved by using a configuration adaptor. It provides iTools with the ability to communicate with and configure devices without any power being connected.


iTools Wizard
Used to simplify the set up of 3200i series indicators, the wizard guides the user through the configuration process with interactive help and graphical demonstrations of features.

SCROLLING MESSAGING ALARM COLOR CHANGE
MESSAGE ALERTS ACTIVATED BY ANY PARAMETER FAST VISUAL PROCESS INDICATION
The 32h8i includes all the features you have come to expect from Eurotherm's alarming indicator PLUS 15 scrolling configurable alarm, warning and/or information messages which can be activated by any parameter. The 32h08i display has a dual line display, with a full 5 digit LCD display on the upper line, and a 9 character messaging display on the lower line. The upper display can be software configured for a RED or GREEN display, as well as to change from GREEN to RED on activation of an alarm, for fast visualisation of alarm status.
ENGINEERING UNITS UNIVERSAL INPUT
 ADD ANY ENGINEERING UNITS REQUIRED  T/C, RTD, mV, mA, V and STRAIN GAUGE (Opt)
In place of paste on units or fixed Deg C or % unit symbols being shown on an indicator, the 32h8i provides for 38 standard engineering units plus  Eurotherm provides the user with a 9 character alpha numeric display field to add the units required. The iTools Wizard allow the operator to simply type in the required units, which are then displayed on the second line of the 32h8i The 32h8i is designed to make it easy to interface all standard process and temperature inputs with the one powerful unit. The 32h8i can directly accept 11 types of Thermocouple, Pt100, mA, mV and 0-10V. An option for the 32h8i will also allow for strain-gauge or load cell connection. For powering a 4-20mA field transmitter, a 24Vdc auxiliary supply is provided a standard.