3100/3150 - MCM Modbus Communications Module

For Allen-Bradley PLC® and SLC® Platforms
(J-Bus Master functionality also supported)


. . The Modbus Communication Module allows the user to easily configure each of its two ports as either a Modbus Master or Slave

Product Description
The 3100-MCM (PLC) and the 3150-MCM (SLC) Modbus Communication Modules are single slot solutions for the A-B 1771 and 1746 platforms. By providing configurable access to both ports, these products provide previously unavailable functionality and versatility.

Simple to Use
All module setup and operating control is performed over the backplane through simple ladder logic and data table configuration. The only software necessary is a standard ladder programming package.

Port Configuration
The two Modbus ports are configured independently, allowing the module to operate in any one of the following configurations: Master/Master, Master/Slave, and Slave/Slave. Once configured, the module will perform all protocol related functions on a stand alone basis.

NEW! Advanced Heater Diagnostics
When the Series 2000 instruments are used with the TE10S Contactors, complete heater diagnostics can be communicated to the Allen-Bradley PLC. This includes: heater amperage, fuse status, contactor health, and load health. The Eurotherm diagnostics are multiplexed onto the existing signal wires via the new PDSIO™ technology... a patented design by Eurotherm.

When the 2301 product is used, the PID control and SSR operate as one PID I/O block that can be installed anywhere on the machine. The 2301 uses the exact same communications capability as the Series 2000 products and the PDSIO heater diagnostics continue to monitor the health status of the SSR, heater and fuse while transmitting the amperage information to the ProSoft interface.

The TU SCR family is used when the PLC is supervising a high quantity of SCR power controllers such as in a paint drying production line. The PLC can use one ProSoft communications port to download setpoints and to monitor the SCRs which might be activating 10-50 infrared heaters.

Example Applications
Applications involving the Modbus Communication Module can be found in many industrial sectors and in the following applications:

  • Foreign Device Data Concentrator
  • Pipelines and Offshore Platforms
  • Food Processing
  • Mining
  • Pulp and Paper

MCM Application Note - Master Mode is available for this product
MCM Application Note - Slave Mode (available soon)

Eurotherm Controls Inc
Series 2000™
with Modbus Communications
Up to 31 controllers per MCM port
Instruments include:
2216, 2208, 2204, 2216e, 2208e, 2204e, 2416, 2408, 2404, 2500, 2604, 2704
TU SCR
Communicating SCRs

Installation, Setup, and Operation
The ProSoft module capabilities are enabled and controlled with simple ladder logic and data table initialization. Each product is shipped with a user's manual detailing the installation and operation of the module. A sample ladder program is provided on disk in order to ease implementation an application note for these products is available, or is available off of the ProSoft ftp server:

For the PLC platform: MCM Master Mode for PLC
For the SLC platform: MCM Master Mode for SLC
ProSoft Test Report: Using a Eurotherm Series 2000™ instrument and the 3100 module
FTP sample download: Ladder logic for PLC-5 to Eurotherm Series 2000™
FTP sample download: Ladder logic for SLC-500 to Eurotherm Series 2000™

Specifications
This product supports the following general capabilities:

  • Up to 100 entries in the command list, each fully configurable for function, slave address, register to/from addressing and word/bit count (Master port)
  • Continuous polling of command list (Master port)
  • Support for the storage and transfer of up to 4000 registers to/from the PLC
  • Event driven bit and register write commands (Master port)
  • Full radio, modem and multi-drop support
  • Supports RS-232C, RS-422 and RS-485 interfaces
  • Communication error codes and counters returned to ladder logic (Slave port)
  • Communication error codes returned to ladder logic on a per command basis (Master Port)

The following Modbus features have been implemented in both configurations:

  • RTU mode (binary) with CRC-16
  • ASCII mode with LRC error checking
  • Broadcast commands
  • 125 word reads and writes
  • Floating Point data movement supported
  • Function Codes Supported:
    • 1 : Read Output Status
    • 2 : Read Input Status
    • 3 : Read Multiple Data Registers
    • 4 : Read Input Registers
    • 5 : Force Single Coil (Write Single Bit)
    • 6 : Preset (Write) Single Data Register
    • 15 : Force Multiple Coils (Write Multiple Bits)
    • 16 : Preset (Write) Multiple Data Register
  • Configuration via simple ladder logic (Example provided with each product)
  • Communication Parameters:
    • Address: 1 to 247
    • Parity: None, Odd, Even
    • Stop Bit: 1 or 2
    • Baud Rate: 300 to 38.4K
    • Mode: RTU or ASCII

ORDERING INFORMATION

This product is available in the following configurations:

For 1771 Platform (PLC 2, 3, & 5)

  • 3100-MCM, Modbus Communication Module

For 1746 Platform (5/02 Minimum)

  • 3150-MCM, Modbus Communication Module

PLC®, PLC-2, PLC-3, PLC-5, and SLC are registered trademarks of the Allen-Bradley company.



FOR EUROTHERM CONTROLS INFORMATION:
Contact your local Eurotherm representative or
Eurotherm Controls Inc
phone: (703) 669-1313
e-mail: mark.demick@eurotherm.com
web site: www.eurotherm.com

FOR PROSOFT TECHNOLOGY, INC. INFORMATION:
contact ProSoft at:
phone: (805) 664-7208
fax: (805) 664-7233
e-mail: prosoft@psft.com
web site: www.psft.com

For a copy of an installation book for using the ProSoft module + Eurotherm's Series 2000 instruments click here.

Attached is an RSLogix 500 project file that was used in the generation of the ProSoft application note. It is a compressed file of RS1 type which includes the RSS type file and all database files. It is valid only for the SLC 500. Please download, unzip, and use the RSLogix 500 tool kit to open this project. Click here to download the zipped file.



大连爱克新仪器有限公司

主 页
| 产品信息 | 工业应用 | 技术支持 | 联系我们 |维修

Copyright © Dalian Action Instruments Co., LTD.

辽ICP备05015478号

市场部:(0411)82650498-801
sales@eurotherm.com.cn
电话:86-411-82650498 传真:86-411-82650478
地址:辽宁省大连市中山区七七街23号海鹰大厦403室(116001)

产品事业部:(0411)82650498-805
support@eurotherm.com.cn